Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Microbiol ; 57(3)2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30567751

RESUMO

Microbiological testing, including interpretation of antimicrobial susceptibility testing results using current breakpoints, is crucial for clinical care and infection control. Continued use of obsolete Enterobacteriaceae carbapenem breakpoints is common in clinical laboratories. The purposes of this study were (i) to determine why laboratories failed to update breakpoints and (ii) to provide support for breakpoint updates. The Los Angeles County Department of Public Health conducted a 1-year outreach program for 41 hospitals in Los Angeles County that had reported, in a prior survey of California laboratories, using obsolete Enterobacteriaceae carbapenem breakpoints. In-person interviews with hospital stakeholders and customized expert guidance and resources were provided to aid laboratories in updating breakpoints, including support from technical representatives from antimicrobial susceptibility testing device manufacturers. Forty-one hospitals were targeted, 7 of which had updated breakpoints since the prior survey. Of the 34 remaining hospitals, 27 (79%) assumed that their instruments applied current breakpoints, 17 (50%) were uncertain how to change breakpoints, and 10 (29%) lacked resources to perform a validation study for off-label use of the breakpoints on their systems. Only 7 hospitals (21%) were familiar with the FDA/CDC Antibiotic Resistance Isolate Bank. All hospitals launched a breakpoint update process; 16 (47%) successfully updated breakpoints, 12 (35%) received isolates from the CDC in order to validate breakpoints on their systems, and 6 (18%) were planning to update within 1 year. The public health intervention was moderately successful in identifying and overcoming barriers to updating Enterobacteriaceae carbapenem breakpoints in Los Angeles hospitals. However, the majority of targeted hospitals continued to use obsolete breakpoints despite 1 year of effort. These findings have important implications for the quality of patient care and patient safety. Other public health jurisdictions may want to utilize similar resources to bridge the patient safety gap, while manufacturers, the FDA, and others determine how best to address this growing public health issue.


Assuntos
Antibacterianos/farmacologia , Técnicas Bacteriológicas/normas , Carbapenêmicos/farmacologia , Farmacorresistência Bacteriana , Infecções por Enterobacteriaceae/epidemiologia , Infecções por Enterobacteriaceae/microbiologia , Enterobacteriaceae/efeitos dos fármacos , Administração em Saúde Pública , Humanos , Los Angeles/epidemiologia
2.
Bone Joint J ; 99-B(7): 865-871, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28663390

RESUMO

AIMS: A contact patch to rim (CPR) distance of < 10 mm has been associated with edge-loading and excessive wear. However, not all arthroplasties with a low CPR distance show problems with wear. Therefore, CPR distance may not be the only variable affecting the post-operative metal ion concentrations. PATIENTS AND METHODS: We used multiple logistic regression to determine what variables differed between the patients who had high and low cobalt (CoS) and chromium (CrS) serum ion concentrations within a cohort of patients with low (< 10 mm) CPR distances. A total of 56 patients treated with unilateral hip resurfacing arthroplasty (HRA) had CoS and CrS ion studies performed more than one year after surgery. The mean age of the patients at the time of surgery was 51.7 years (29 to 70), with 38 women (68%) and 18 men (32%). RESULTS: It was seen that 47 patients had low ion levels (< 7µg/L) and nine had high ion levels (≥ 7µg/L). We found increased risks of high wear with decreasing CPR distance. CONCLUSION: The use of CPR distance measurements to predict hips at risk for elevated wear is needed for all patients with HRA. We recommend that patients with low CPR distances have at least one serum ion study performed while patients with CPR distance > 10 mm do not need routine ion studies. We believe that patients with low CPR distance and low ions do not need repeat ion studies unless the patient becomes symptomatic or has substantial radiographic changes. Cite this article: Bone Joint J 2017;99-B:865-71.


Assuntos
Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Falha de Prótese , Adulto , Idoso , Fenômenos Biomecânicos , Cromo/sangue , Cobalto/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fatores de Risco
3.
Acta Orthop Belg ; 82(3): 516-521, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29119892

RESUMO

There is a paucity of information regarding the clinical performance of the fully cementless metal-on-metal hip resurfacing designs. We compared the biomechanical reconstruction between the two hips of a group of patients treated with a hybrid resurfacing design on one side and a new, fully cementless version of the same resurfacing design on the other side.We retrospectively identified 20 patients with a hybrid hip resurfacing on one side and a fully cementless device on the contralateral side. The cemented femoral components were implanted with a target angle stem to shaft angle of 140° while the cementless femoral components were implanted with the aim to replicate the natural neck to shaft angle.No significant differences were observed post-operatively in femoral offset or leg length despite implantation with a larger metaphyseal stem to femoral shaft angle in the hybrid group. Both hybrid and cementless designs provide similar biomechanical reconstructions.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Próteses Articulares Metal-Metal , Osteoartrite do Quadril/cirurgia , Adulto , Fenômenos Biomecânicos , Feminino , Necrose da Cabeça do Fêmur/cirurgia , Luxação Congênita de Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...